ブルカー・ダルトニクス
製品案内 アプリケーション 会社概要 サポート イベント情報 リクルート お問い合わせ
製品案内
製品一覧
MALDI-TOF MS
microflex & microflex LT
ultraflex III & ultraflex III TOF/TOF
autoflex III & autoflex III TOF/TOF
ESI-Ion Trap MS
esquire6000
HCT
HCTultra
HCTultra PTM Discovery System
ESI-(Q-) TOF
micrOTOFfocus
micrOTOF-Q
FTMS & Qh-FTMS
APEX-Qe
Solution Packages
PROTEINEER
GENOLINK
ClinProt
CARE
Consumables, Accessories,Robotics, Software
CARE 商品価格表 PDF
think forward
esquire6000
高性能ESI-Ion Trap MSn システム
esquire6000 今日、研究者には、LC/MSnの明確な要求があります。高感度と高速スキャンがHPLCの各ピークから得られる情報を最大限に引き出します。
データ解釈と管理を簡素化する賢いソフトウェアツール。
増加するサンプル数とスループットの直線的な作業フロー。
傑出したスキャンパワー、感度、および便利さでどうこれらの必要性に答えるかを見てください。
Industry-leading scan power
Explore the high performance of our 3rd generation benchtop ion trap. Perform rapid sample screening, as well as detailed structural and quantitative investigations.
Applications-driven software suite
Utilize powerful software tools for quick and intuitive method setup, data interpretation and reporting of results.
An analytical platform tailored to your needs
Benefit from the esquire‘s smooth integration with a broad variety of LC systems, sample preparation modules, and API sources.
■Chromatography Choices
The most widely used LC systems, autosamplers and fraction collectors are now fully integrated with the esquire6000: The Compass software enables complete and intuitive LC/MS method setup and system control.
The esquire6000 can be coupled to the Capillary Electrophoresis systems and is part of the world‘s first fully-integrated LC-NMR/MS system introduced by Bruker Biospin and Bruker Daltonics.
■Ion Sources
The esquire6000 uses the Agilent electrospray (ESI) ion source, which provides outstanding robustness, sensitivity and reproducibility over a wide range of LC operating conditions.
The orthogonal sprayer design speeds up method development while minimizing chemical noise, regardless of the separation conditions. The rugged design with fixed sprayer position prevents contamination and thus extends the maintenance cycle time.
Enhanced sensivitity for all applications down to the very low pg limit is possible. Tuning has become easier and largely uncritical across a wide m/z range.
Switching between all sources is fast and easy, due to the hinged swingout spray chamber design. A whole varitey of API sources covers the widest range of LC/MS applications, including various low-flow options.
■The Ion Trap
Superior combination of mass range, scan speed and resolution.
The ion trap continues to offer the unrivaled standard mass range up to m/z 3000. Monoisotopic resolution throughout this standard mass range gives you the full picture at once. The extended mass range reaches up to m/z 6000.
Fast scanning
Ultrafast scan cycles for both MS and MS/MS account for an extremely high duty cycle. More than 100 mass scans can be captured across a typical LC peak. This fast scanning also improves the dynamic range and reduces measurement variance.
MSn performance
Fragmentation is supported up to the MS11 stage, allowing for detailed investigation of target compounds. Monoisotopic isolation is ensured throughout the standard mass range.
Sensitivity
The highly efficient ion transfer and trapping, as well as short scan times contribute to the truly superior sensitivity in the low pg range.
Multiple stages of structural information
Multiple fragmentation experiments up to MS11 help to gather structural information on ingredients of natural products, drugs, food and other samples. Because of the single-step dissociation in an ion trap, fragmentation pathways can be elucidated easily by MSn. An optional Wide-band Fragmentation™ across a m/z range of up to 300 u ensures the simultaneous fragmentation of the precursor and ions which are derived from the pure loss of water or amine groups if those occur dominantly.
Fully automated ion-tree experiments and data-dependent scans help gaining structural information very quickly. In order to extract only the most relevant information, intelligent AutoMS/MS options can be used for MS/MS precursor ion selection and fragmentation.
■Applications
Automated Protein Identification
In-Depth Protein Characterization
Intelligent data acquisition in Proteomics
Structural Confirmation
Quantitation from complex samples
Metabolite Screening
■Technical specifications
Proven esquire technology
Unparalleled combination of resolution, scan speed, and mass range in MS and MSn.
Superior mass accuracy.
Low pg MS and MS/MS sensitivity.
Fast Polarity Switching for on-the-fly acquisition of positive and negative ions.
SmartFrag™ creates reproducible MS/MS spectra for successful MS/MS library search.
Scan speed and resolution (MS and MS/MS)
Scan Mode Resolution FWHM (u) m/z u/sec
Standard 0.6 50-3000 13.000
Enhanced 0.45 50-3000 5.500
Maximum Res. 0.35 50-3000 1.650
Extended 2-4 200-6000 27.000
Scan modes
Full scan MS and MS/MS in all scan modes for sensitive and fast analysis of unknown compounds.
Neutral loss scans e.g. for determination of protein modifications.
Multiple reaction monitoring (MRM) with MS/MS and MS3.
Manual MSn up to MS11 in all scan modes.
AutoMSn tree experiments with up to 30 MS precursor ions and 5 fragment ions per stage.
Triple Play experiments without time consuming “charge-state determination-scan“.
Data-dependent experiments
All types of data-dependent experiments, including preferred mass list for automated feedback experiments from MetaboliteTools and PROTEINEER.
Active Exclusion
Passive Exclusion
Maximum Resolution Scan
Triple Play experiments without time consuming "charge-state determination-scan"
Preferred mass list
Preferred charge state
Chromatography Choices
Integrated LC-MS control provided for:
Agilent 1100 HPLC series, Capillary LC, nanoLC
Waters Alliance HPLC series, CapLC, PDA
LC Packings nanoLC systems (1D and 2D)
Gilson 215 Autosampler/Fraction Collector
Spark Endurance Autosampler
CTC Analytics HTS PAL Autosampler
Source Options
ESI - Orthogonal electrospray ionization source
APCI - Orthogonal atmospheric pressure chemical ionization source
Online NanoElectrospray - for capillary LC flow down to 50 nL/min
Offline NanoElectrospray - consumption of 1-2 uL per sample at a flow rate of ca. 25 nL/min
AP-MALDI - Atmospheric pressure MALDI source
APPI - Atmospheric pressure photo ionization source
Smart CE-MS coupling with grounded needle
COMPASS - Software Features
Integrated LC-MS control and data processing, including HyStar™, esquireControl™, DataAnalysis™, QuantAnalysis™, LibrarySearch™ modules.

Software options:
MetaboliteTools™ software for metabolite identification
BioTools™/RapiDeNovo™ software for protein data interpretation
ProteinScape™ database system for proteome project management
ACD Labs MS Manager
Compass Security Pack for work in regulated environment
■Related Products
Compass
Unified software environment
PROTEINEER
Mass Spectrometry-Based Proteomics Suite
BioTools/RapiDeNovo
Protein Data Analysis Package
ProteinScape
Database System for Proteomics Project Management
MetaboliteTools
Software for Metabolite Identification
PROTEINEER spII
Automated Spot Picker
PROTEINEER dp
Digest & Prep Workstation
ProfileAnalysis
Software for profiling and statistical evaluation of LC/MS data sets
■Further Reading
Application Note LCMS-38
High sensitivity protein identification using an AP MALDI source on the esquire
Application Note LCMS-43
Identification of Proteins from Taxus baccata: A Species with a Non-Sequenced Genome
Brochure esquire6000
NEXT
PAGE TOP
BrukerDaltonics GLOBAL WEBSITE Copyright ©2008 Bruker Daltonics Updated: 2008年6月13日
ブルカー・ダルトニクス ブルカー・ジャパン